Steel square
<templatestyles src="Module:Hatnote/styles.css"></templatestyles>
The steel square is a tool that carpenters use. They use many tools to lay out a "square" or right-angle, many of which are made of steel, but the title steel square refers to a specific long-armed square that has additional uses for measurement, especially of angles, as well as simple right-angles. Today the steel square is more commonly referred to as the framing square. It consists of a long arm and a shorter one, which meet at an angle of 90 degrees (a right angle). It can also be made of metals like aluminum, which is light and resistant to rust.
The wider arm, two inches wide, is called the blade; the narrower arm, one and a half inches wide, the tongue. The square has many uses, including laying out common rafters, hip rafters and stairs. It has a diagonal scale, board foot scale and an octagonal scale. On the newer framing squares there are degree conversions for different pitches and fractional equivalents.
Framing squares may also be used as winding sticks.
Contents
- 1 Blade and tongue
- 2 Use in stair framing
- 3 Use in roof framing
- 4 Use of the octagon scale
- 5 Use of the Diagonal scale
- 6 Using calculators in roof framing
- 7 Side cut hip/valley rafter table
- 8 Side cut of jack rafters
- 9 Plumb cut of jack & common rafters
- 10 Plumb cut of hip/valley rafters
- 11 Irregular hip/valley rafters
- 12 Carpenter's square
- 13 See also
- 14 Bibliography
Blade and tongue
In traditional timber frame joinery, mortises and tenons were typically two inches wide and two inches from the edge of the timber when working with softwoods, giving rise to the width of the blade. Likewise, mortises and tenons were traditionally one and a half inches wide when working in hardwoods, explaining the width of the tongue. This allowed for quick layouts of mortise and tenon joints when working both hard and softwoods.
Use in stair framing
Stairs usually consist of three components. They are the stringer, the tread and the riser. The stringer is the structural member that carries the load of the staircase, the tread is the horizontal part that is stepped on, and the riser board is the vertical part which runs the width of the structure. There are many types of stairs: open, closed, fully housed, winding, and so on, to mention a few of them.
Laying out a staircase requires rudimentary math. There are numerous building codes to which staircases must conform. In an open area the designer can incorporate a more desirable staircase. In a confined area this becomes more challenging. In most staircases there is one more rise than there are treads.
- The rise (vertical measurement), and the run (horizontal measurement). Note that the stringer will rest partially on the horizontal surface.
- This is a two-by-twelve piece of lumber. A framing square is placed on the lumber so that the desired rise and tread marks meet the edge of the board. The outline of the square is traced. The square is slid up the board until the tread is placed on the mark and the process is repeated.
- The board is cut along the dotted lines, and the top plumb cut and the bottom level cut are traced by holding the square on the opposite side.
- The stringer in this example has two pieces of tread stock. This allows for a slight overhang. There is also a space in between the boards. The bottom of the stringer must be cut to the thickness of the tread. This step is called dropping the stringer. After one stringer is cut this piece becomes the pattern that is traced onto the remaining stringers.
Use in roof framing
18" | 17" | 16" | 15" | 14" | 13" | 12" | 10" | 9" | 8" | |
---|---|---|---|---|---|---|---|---|---|---|
Common rafter length per foot run | 21.63" | 19.21" | 16.97" | 14.42" | ||||||
Hip or valley rafter length per foot run | 24.74" | 22.65" | 20.78" | 18.76" | ||||||
Difference in length of jacks 16 inch centers | 28.88" | 25.63" | 22.63" | 19.25" | ||||||
Difference in length of jacks 24 inch centers | 43.25" | 38.44" | 33.94" | 28.88" | ||||||
Side cut length of jack rafters | 6.69" | 7.5" | 8.5" | 10.00" | ||||||
Side cut of hip rafter or valley rafter | 8.25" | 9.0" | 9.81" | 10.88" | ||||||
This table shows five different types of rafter calculations and one table for marking an angle called the side cut or cheek cut. |
There is a table of numbers on the face side of the steel square; this is called the rafter table. The rafter table allows the carpenter to make quick calculations based on the Pythagorean theorem. The table is organized by columns that correspond to various slopes of the roof. Each column describes a different roof inclination (pitch) and contains the following information:
- Common rafter per foot of run. The common rafter connects the peak of a roof (the ridge) to the base of a roof (the plate). This number gives the length (hypotenuse) of the common rafter per twelve units of horizontal distance (run).
- Hip or valley rafter per foot of run. The hip or valley rafter also connects the ridge to the plate, but lies at a 45-degree angle to the common rafter. This number gives the length of the hip or valley rafter per seventeen units of run.
- Difference in lengths jacks. The jack rafters lie in the same plane as the common rafter but connect the top plate (the wall) or ridge board to the hip or valley rafter respectively. Since the hip or valley rafter meets the ridge board and the common rafter at angles of 45 degrees, the jack rafters will have varying lengths when they intersect the hip or valley. Depending on the spacing of the rafters, their lengths will vary by a constant factor—this number is the common difference.
- This angle can be cut on the fly by aligning this given number on the blade of the steel square and the twelve-inch mark on the tongue, and drawing a line along the tongue.
- Cutting hip and valley criple rafters are all cut in a similar way.
Use of the octagon scale
-
Scribe an Octagon.jpg
Octagon made from the Octagon scale. A protractor can accomplish the same task.
Use of the Diagonal scale
Knee bracing is a common feature in timber framing to prevent racking under lateral loads. The diagonal scale is useful for determining the length of the a knee brace desired for a given distance from the joint between the bost and beam.
Using calculators in roof framing
In addition to use the square tool, construction calculators are also used to verify and determine roofing calculations. Some are programmed to calculate all side cuts for hip, valley and jack regular rafters to be exactly 45° for all rafter pitches. The rafter table is expressed in inches, and the higher the numerical value of the pitch, the greater the difference between side cut angles within a given pitch. Only a level roof, or a 0 pitch will require a 45° angle side cut (cheek cut) for hip and jack rafters.
Side cut hip/valley rafter table
If a right triangle has two angles that equal 45° then the two sides are equidistant. The rafter is the hypotenuse and the legs or catheti of the triangle are the top wall plates of the structure. The side cut is located at the intersection of the given pitch column and the side cut of the hip/valley row. The regular hip/valley rafter runs at a 45° angle to the main roof and the unit of measurement is 16.97 inches of run. Regular hip/valley and jack rafters have different bevel angles within any given pitch and the angle decreases as the pitch increases.
Legend | ||
---|---|---|
|
The side cut of the hip/valley rafter = (Tangent)(12) = side cut in inches. The side cuts in the rafter table are all in a base 12. The arc tan can be determined from any given pitch. Most power tools and angle measuring devises use 90° as 0° in construction. The complementary angles of the arc tan are used with tools like the speed square.
Side cut of jack rafters
The side cut is located at the intersection of the side cut of jack rafters row and the pitch column on the Steel square. There is a row for the difference in length of jacks, 16 and 24 inch centers on the blade. The tangents are directly proportional for both centers.
The tangent is in a base 12. The tangent x 12 = side cut of jack rafters. This corresponds to the side cut on the Steel square. The complementary angles of the arc tan are used on most angle measuring devises in construction. The tangent of hip, valley, and jack rafters are less than 1.00 in all pitches above 0°. An eighteen pitch has a side cut angle of 29.07° and a two pitch has a side cut angle of 44.56° for jack rafters. This is a variation of 15.5° between pitches.
Plumb cut of jack & common rafters
The plumb cut for jack and common rafters are the same angles. The level cut or seat cut is the complementary angle of the plumb cut. The notch formed at the intersection of the level and plumb cut Is commonly referred to as the bird’s mouth .
Plumb cut of hip/valley rafters
The plumb cut of the hip/valley rafter is expressed in the formula. The level cut is the complementary angle or 90° minus the arc tan.
Irregular hip/valley rafters
The only Framing Square that has tables for unequal pitched roofs is the Chappell Universal Square, (patent #7,958,645). There is also a comprehensive rafter table for 6 & 8 sided polygon roofs (first time ever on a framing square). The traditional steel square's rafter table (patented April 23,1901) is limited in that it does not have tables that allow for work with unequal pitched roofs. Irregular hip/valley rafters are characterized by plan angles that are not equal or 45°. The top plates can be 90° at the outside corners or various other angles. There are numerous irregular h/v roof plans.
Carpenter's square
In carpentry, a square or set square is a guide for establishing right angles (90° angles), usually made of metal and in the shape of a right triangle.
See also
Bibliography
Wikimedia Commons has media related to Steel squares. |
- Lua error in package.lua at line 80: module 'strict' not found.
- Lua error in package.lua at line 80: module 'strict' not found.
- Lua error in package.lua at line 80: module 'strict' not found.
- Lua error in package.lua at line 80: module 'strict' not found.
- Lua error in package.lua at line 80: module 'strict' not found.
- Lua error in package.lua at line 80: module 'strict' not found.
- Lua error in package.lua at line 80: module 'strict' not found.
- Lua error in package.lua at line 80: module 'strict' not found.